15-09-2021

  1. Iso 2859 1 Free
  2. Copy Of Iso 2859 1 Free Download
  3. Iso 2859-2
  4. Copy Of Iso 2859 10

Corrigendum 1

Available for SubscriptionsAvailable in Packages
  • ISO 2859-Sampling Procedures for Inspection by Attributes Package
Please first log in with a verified email before subscribing to alerts.

Tabel 1 – Codeletters voor de steekproefgrootte overeenkomstig DIN ISO 2859-1 General inspection level II is the most widely acceptable level for moulded glass bottles. Table 2 -Single sample plans for normal inspection according DIN ISO 2859-1. Full Description. This part of ISO 2859 specifies an acceptance sampling system for inspection by attributes. It is indexed in terms of the acceptance quality limit (AQL). Its purpose is to induce a supplier through the economic and psychological pressure of lot non-acceptance to maintain a process average at least as good as the specified acceptance quality limit, while at the same time providing an upper. “Four additional special levels, S-1, S-2, S-3 and S-4 may be used where relatively small sample sizes are necessary and larger sampling risks can be tolerated” (ISO 2859-1 standard). Under S-3 level, the number of samples to check is lower than under S-4, and so on. May 09, 2012 Finally, it is worth noting that the Codex Alimentarius recommends the use of the ISO 2859 series relating to the procedures for sampling by attributes and the ISO 3951 series for the procedures for sampling by variables. Economic Evaluation of ISO 2859 Acceptance Sampling Plans Used with Rectifying Inspection of Rejected Lots.

Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.

Please first verify your email before subscribing to alerts.

Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.

Already Subscribed to this document.

Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.

Documents sold on the ANSI Webstore are in electronic Adobe Acrobat PDF format, however some ISO and IEC standards are available from Amazon in hard copy format.
Some PDF files are protected by Digital Rights Management (DRM) at the request of the copyright holder. You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Some copyright holders may impose other restrictions that limit document printing and copy/paste of documents.
Those documents cannot be printed at the request of the copyright holder.

Content Provider
International Organization for Standardization [ISO]

The Acceptance Quality Limit (AQL) is a proven statistical instrument at the disposal for quality control when it comes to evaluating product quality.

The need for quality control

In virtually every production batch, there will be defective products - however they could be extremely rare. There will always be defective products even after the QC has checked and repaired each individual product. Flawless products only exist in a perfect world, the goal is to create products that are within acceptable tolerances. Although the quality assurance systems of manufacturers of primary packaging materials are becoming increasingly more efficient through the use of innovative technologies, such as electronics and laser refraction modules, there will always be room for improvement and there are always ways to make it even better; each production run is another opportunity to create new quality standards. Notwithstanding the fact that a buyer always want a zero defect product, the supplier cannot be expected to deliver absolute zero defect goods. However, the buyer wants to control the consistent quality of purchased goods, since it does not want (too many) defects.

AQL background

Not each and every individual product can be fully checked as to its functionality. Products would become highly expensive or even instantly obsolete, as destructive test methods would destroy the product. For this reason acceptance sampling has been developed. Acceptance sampling is a statistical quality control instrument that represents a compromise between doing no inspection and a full inspection. Acceptance sampling originated way back, even before the Second World War, when the US military had to determine which batches of ammunition to accept and which bullets to reject by a destructive test method. The US army therefore developed the Military Standard 105-D, testing a few representative bullets from the production batch so they could trust the other bullets would perform on the battle field. Ultimately this might mean the difference between life and death.

The sampling scheme by which representative samples (sample rate) are selected from a population (production batch/lot) and tested to determine whether a production batch/lot is acceptable or has to be rejected is known as an acceptance plan or sampling plan administrated??? according to DIN ISO 2859 part 1. Hence the AQL, defined as the quality level that is the lowest acceptable, is a statistical procedure for determining production batch/lot quality.

Iso

AQL standard for moulded glass

Primary packaging materials made of moulded glass for pharmaceutical and cosmetic purposes are often manufactured according to quality agreements based on the 'Defect Evaluation List for Containers Made of Moulded Glass' and to the appropriate GMP Rules of the WHO (see 'Editio Cantor' )

Acceptable defect level:

Om het maximum aantal ondeugdelijke eenheden (het acceptabele aantal ondeugdelijke producten) te bepalen, moet een kwaliteitsinspecteur weten:

  • The production batch/lot size
  • The inspection level
  • The random sample size
  • The AQL portion

To determine the correct sampling plan and acceptance/rejection level, quality inspectors rely on basically two AQL tables:

  1. The first table determines which 'code letter' to use based on the inspection level and production batch/lot size.
  2. The second table determines the sample size and maximum number of defects that can be accepted based on the code letter and AQL.
Tabel 1 – Codeletters voor de steekproefgrootte overeenkomstig DIN ISO 2859-1

General inspection level II is the most widely acceptable level for moulded glass bottles.

Table 2 -Single sample plans for normal inspection according DIN ISO 2859-1

Iso 2859 1 Free

Classification

The most widely acceptable defect classes and AQL portions for moulded glass:

  • Defect class 1, critical defect; Consequently AQL defect portion -
    • Consequence: Packaging material not usable
  • Defect class 2A, major defect; Consequently AQL defect portion 0.65
    • Consequence: Usability of packaging material markedly impaired
  • Defect class 2B, major defect; Consequently AQL defect portion 1.5
    • Consequence: Usability of packaging material moderately impaired
  • Defect class 3, Minor defect; Consequently AQL defect portion 6.5
    • Consequence: Usability of packaging material slightly impaired

Defect counting rules:

The number of defects found for each defect class is typically calculated according to the following procedure:

  • Each individual defect is counted.
  • If one bottle has more than one defect, it is only count once.
  • In case multiple defects at one bottle belong to multiple defect classes, the lowest AQL sets the acceptable defect limit.

Example of a defect evaluation

QA have noticed an inside open glass bubble (defect# 14.05.11) in two production batches of 550,000 moulded glass bottles. According to the current defect evaluation list this represent defect class 2A, i.e. an AQL defect portion of 0.65. What would be the correct sample size and the acceptable number of defects?

Counting results for batch 1 (demo)

  • The inspection level is determined to be General inspection level 'II'. Consequently, the code letter is 'Q'. (table 1)
  • Consequently the random sample size from the total production batch is 1,250 units. (table 2)
  • Defect class 2A, major defect; Consequently an AQL defect portion of 0.65
  • Acceptance number of defective bottles is a maximum 14 at an AQL portion of 0.65 (table 2)
  • The rejection number of defective bottles is 15 or more at an AQL portion of 0.65 (table 2)

Resultaten van het tellen bij partij 1 (demo)

Copy Of Iso 2859 1 Free Download

Quality inspectors found the following numbers of defective bottles:

  • 12 bottles with different defect characteristics within defect class 2A
  • 10 bottles with different defect characteristics within defect class 2B
  • 12 defects at defect class 2A is less than the highest acceptable number of defects (14).
  • 10 defects at defect class 2B is less than the highest acceptable number of defects (21 see table 2).

Result: Production batch 1 is release/approved as none of the defect classes (2A and 2B) are met.

Iso 2859-2

Copy Of Iso 2859 1

Counting results batch 2 (demo)

Quality inspectors found the following number of defective bottles:

  • 14 bottles with different defect characteristics within defect class 2A
  • 22 bottles with different defect characteristics within defect class 2B
  • 14 defects at defect class 2A is equal to the highest acceptable number of defects (14).
  • 222 defects at defect class 2B is above the highest acceptable number of defects (21 see table 2).

Result: Production batch 2 is rejected/not approved as one of the defect classes (2A and 2B) is not met.

Copy Of Iso 2859 10

The above examples, counting rules and AQL portions used are for demonstration purposes only.